描述
XSZ PROXIMITY SENSORS
PR08-2DN M8 Non-shielded Proximity Sensor
A compact M8 non-shielded DC proximity sensor range for close-range metal detection, with NPN, PNP, and DC two-wire model choices.
Compact M8 non-shielded sensing
The XSZ PR08-2DN is the M8 non-shielded DC NPN normally open configuration with a listed 2 mm +/-10% sensing distance. The non-shielded M8 matrix also includes NPN, PNP, and DC two-wire normally open and normally closed models.
The supplied M8 product image shows a 35 mm body-length reference and a 5 mm sensing-face diameter. Confirm the connection type and wiring with XSZ before order.

Key product advantages
M8 non-shielded construction
The supplied image shows an M8 construction with a 35 mm body-length reference and a 5 mm sensing-face diameter.
2 mm detection
The non-shielded M8 range is listed with a 2 mm +/-10% sensing distance and a 0-1.6 mm setting distance.
DC output choices
Select the listed NPN, PNP, or DC two-wire normally open or normally closed model code.
Type and Specification
| Type and Specification | ||
|---|---|---|
| Dimension | M8 | |
| Electrical type | Output logic | non-shielded |
| DC type | NPN, NO | PR08-2DN |
| NPN, NC | PR08-2DN2 | |
| PNP, NO | PR08-2DP | |
| PNP, NC | PR08-2DP2 | |
| DC 2-wire type | NO | PR08-2DO |
| NC | PR08-2DC | |
| Sensing distance | 2 mm +/-10% |
|---|---|
| Setting distance | 0-1.6 mm |
| Standard detection target | Iron 12 x 12 x 1 mm |
| Hysteresis | Less than 10% of sensing distance |
| Detectable target | Metal (iron) |
| Supply voltage | DC type: 10-30 VDC (6-36 V); pulse (P-P) less than 10% |
| Consumption current | N.P type: less than 13 mA; D type: less than 0.8 mA. |
| Control output | N.P type: less than 300 mA; D type: less than 200 mA. |
| Circuit protection | N.P.D type: reverse-connection protection, surge absorption, and load short-circuit protection. |
| Ambient temperature and humidity | Operating and storage: -30 to +65 deg C, no freezing or dew; 35-95% RH. |
| Insulation resistance | At least 50 Mohm at DC 500 V megger, between the energized part and housing. |
| Temperature influence | -30 to +65 deg C: within +/-15% sensing distance at +23 deg C; -25 to +55 deg C: within +/-10% at +23 deg C. |
| Voltage influence | Within +/-15% of rated supply-voltage range; within +/-10% sensing distance at rated supply voltage. |
| Protection class | IP67 |
| Material | Housing: nickel-plated brass; sensing face: ABS. |
| Cable and connection | Confirm with XSZ before order |
Where it helps
Selection and installation checklist
- Select the required NPN, PNP, or DC two-wire output logic and NO or NC operation.
- Use the listed 2 mm non-shielded sensing distance and 0-1.6 mm setting distance during installation planning.
- Match the target to the listed iron 12 x 12 x 1 mm standard detection target.
- Confirm cable, connector, wiring, and target compatibility with XSZ before order.
Frequently asked questions
What sensing distance is listed?
The M8 non-shielded configuration is listed at 2 mm +/-10%, with a 0-1.6 mm setting distance.
Which model codes are available?
The non-shielded matrix lists NPN, PNP, and DC two-wire NO and NC model codes. See the table above.
What are the M8 image references?
The supplied image shows a 35 mm body-length reference and a 5 mm sensing-face diameter.
Can XSZ confirm wiring?
Yes. Confirm the cable, connector, wiring arrangement, and target compatibility with XSZ before order.
Need the right M8 non-shielded model?
Send XSZ your required output logic, operating mode, and application details for model confirmation.






Reviews
There are no reviews yet.