描述
XSZ PROXIMITY SENSORS
PR30-10DN M30 Shielded Proximity Sensor
An M30 shielded proximity sensor range for 10 mm close-range detection, with NPN, PNP, DC two-wire, and AC two-wire model choices.
M30 shielded sensing for metal targets
The XSZ PR30-10DN is the M30 shielded NPN normally open configuration with a listed 10.0 mm +/-10% sensing distance. The shielded M30 matrix also includes NPN, PNP, DC two-wire, and AC two-wire normally open and normally closed models.
The supplied reference image marks a 60 mm length, 30 mm diameter, red LED indicator, and two fastening nuts. Confirm the connection type and wiring with XSZ before order.

Key product advantages
M30 shielded construction
The supplied reference shows an M30 threaded sensor with a 60 mm length, 30 mm diameter, and two fastening nuts.
10 mm detection
The shielded M30 range is listed with a 10.0 mm +/-10% sensing distance and a 0-8 mm setting distance.
Output choices
Select NPN, PNP, DC two-wire, or AC two-wire NO or NC model codes according to the electrical requirement.
Type and Specification
| Type and Specification | ||
|---|---|---|
| Dimension | M30 | |
| Electrical type | Output logic | Shielded |
| DC type | NPN, NO | PR30-10DN |
| NPN, NC | PR30-10DN2 | |
| PNP, NO | PR30-10DP | |
| PNP, NC | PR30-10DP2 | |
| DC 2-wire type | NO | PR30-10DO |
| NC | PR30-10DC | |
| AC 2-wire type | NO | PR30-10AO |
| NC | PR30-10AC | |
| Sensing distance | 10.0 mm +/-10% |
|---|---|
| Setting distance | 0-8 mm |
| Standard detection target | Iron 30 x 30 x 1 mm |
| Hysteresis | Less than 10% of sensing distance |
| Detectable target | Magnetic metal; sensing distance decreases for non-magnetic metals. |
| Supply voltage | DC type: DC 12-24 V (6-36 V), pulse (P-P) less than 10%; AC type: AC 110-220 V (36-250 V), 50/60 Hz. |
| Consumption current | N.P type: less than 13 mA; D type: less than 0.8 mA; A type: less than 1.7 mA. |
| Control output | N.P type: less than 300 mA; D type: less than 200 mA; A type: less than 400 mA. |
| Circuit protection | N.P.D type: reverse-connection protection, surge absorption, and load short-circuit protection; A type: surge absorption. |
| Ambient temperature and humidity | Operating and storage: -30 to +65 deg C, no freezing or dew; 35-95% RH. |
| Insulation resistance | At least 50 Mohm at DC 500 V megger, between the energized part and housing. |
| Temperature influence | -30 to +65 deg C: within +/-15% sensing distance at +23 deg C; -25 to +60 deg C: within +/-10% at +23 deg C. |
| Voltage influence | Within +/-15% of rated supply-voltage range; within +/-10% sensing distance at rated supply voltage. |
| Protection class | IP67 |
| Material | Housing: nickel-plated brass; sensing face: ABS. |
| Cable and connection | Confirm with XSZ before order |
Where it helps
Selection and installation checklist
- Select the electrical type, output logic, and NO or NC operation required by the control circuit.
- Use the listed 10.0 mm shielded sensing distance and 0-8 mm setting distance during installation planning.
- Match the target to the listed iron 30 x 30 x 1 mm standard detection target.
- Confirm cable, connector, wiring, and target compatibility with XSZ before order.
Frequently asked questions
What sensing distance is listed?
The M30 shielded configuration is listed at 10.0 mm +/-10%, with a 0-8 mm setting distance.
Which model codes are available?
The shielded matrix lists NPN, PNP, DC two-wire, and AC two-wire NO and NC model codes.
What does the reference image show?
It marks a 60 mm length, 30 mm diameter, a red LED indicator, and two fastening nuts.
Can XSZ confirm wiring?
Yes. Confirm the cable, connector, wiring arrangement, and target compatibility with XSZ before order.
Need the right M30 shielded model?
Send XSZ your required electrical type, output logic, and application details for model confirmation.







Reviews