A 74 x 48 x 15 detection-hole sensor for the source-listed 20 mm hole configuration.
20 mm detection hole
2 mm minimum target
Focused 20 mm selection
This page is arranged around one source-supported version only: the 74 x 48 x 15 housing with a 20 mm detection-hole diameter and 2 mm minimum detection target.
Use the fixed model matrix below to select the required NPN, PNP, DC, or AC code and normally open or normally closed output logic. Confirm cable, wiring, target material, and installation clearance with XSZ before order.
Model selection
Select the electrical type and output logic; each repeated electrical type is grouped for faster comparison.
| Type and Specification | ||
|---|---|---|
| Dimension | 74 x 48 x 15 | |
| Detection-hole diameter | 20 mm | |
| Minimum detection target | 2 mm | |
| Output configuration | Output logic | Model |
| NPN | NO | SZ-M74-M20DN |
| NC | SZ-M74-M20DN2 | |
| PNP | NO | SZ-M74-M20DP |
| NC | SZ-M74-M20DP2 | |
| DC | NO | SZ-M74-M20DO |
| NC | SZ-M74-M20DC | |
| AC | NO | SZ-M74-M20AO |
| NC | SZ-M74-M20AC | |
Dedicated size data
Only the 20 mm hole configuration is shown, avoiding mixed size comparisons.
Clear output mapping
The table maps every listed NO and NC code without changing the source model numbers.
Practical adjustment
The supplied parameters list side potentiometer sensitivity adjustment and IP67 protection.
Operating parameters
| Consumption and load | Consumption current: 15 mA Maximum load current: 100 mA at DC 24 V |
|---|---|
| Circuit protection | N/P/D type: reverse-connection protection, surge absorption, and load short-circuit protection |
| Supply voltage | DC: 12-24 V (6-36 V); ripple (P-P) less than 10% AC: 110-220 V (36-250 V), 50/60 Hz |
| Temperature and humidity | Operating and storage: -30 to +65 deg C, no freezing or condensation Operating and storage humidity: 35-95% RH |
| Electrical safety | Insulation resistance: at least 50 Mohm at DC 500 V, between energized parts and housing Withstand voltage: AC 1000 V, 50/60 Hz, 1 minute, between energized parts and housing |
| Temperature and voltage influence | Temperature: -30 to +65 deg C, within +/-15% of sensing distance at +23 deg C; -25 to +60 deg C, within +/-10% at +23 deg C Voltage: within +/-15% of rated supply-voltage range; within +/-10% sensing distance at rated supply voltage |
| Sensitivity adjustment | Side potentiometer adjustment |
| Protection class and housing | Protection class: IP67 (IEC) Housing: ABS |
Applications and ordering support
Where it can be considered
- Part-through detection stations
- Assembly equipment
- Material-handling stations
Confirm the target material and installation conditions with XSZ before order.
Selection checklist
- Confirm 74 x 48 x 15 housing size.
- Confirm the 20 mm hole and 2 mm target reference.
- Choose NPN, PNP, DC, or AC and NO or NC logic.
- Confirm cable, wiring, and clearance with XSZ.
Frequently asked questions
What hole diameter is included?
This page contains only the source-listed 20 mm detection-hole configuration.
What target reference is listed?
The selected configuration lists a 2 mm minimum detection target.
Which output types are available?
The source lists NPN, PNP, DC, and AC models with NO and NC output logic.
What should be confirmed before order?
Confirm cable, wiring, target material, and installation clearance with XSZ before order.
Need 20 mm selection support?
Send XSZ your output requirement, supply information, and installation conditions for confirmation.








Reviews
There are no reviews yet.